PV Array Simulation (NS91000)

Solar Array Simulator DC Power Supply

PV Array Simulation (NS91000). I-V and P-V curve generation with EN50530 static/dynamic, Sandia, weather and shadow tests.

Specifications

Technical specifications (representative)
Output voltage range 0 – rated (360 / 500 / 750 / 1000 / 1500 / 2250 V)
Output current Bidirectional ± rated (to 240 A / unit, to 2400 A in cabinet)
Output power Bidirectional ± rated (14 kW–420 kW; MW via parallel)
Operating quadrants Dual-quadrant (source + regenerative sink), seamless crossover
Regenerative efficiency Up to 93% (energy returned to grid)
CV setting accuracy ≤ 0.02% + 0.02% F.S.
CC / CP setting accuracy ≤ 0.1% + 0.1% F.S.
Voltage readback accuracy ≤ 0.02% + 0.02% F.S.
Dynamic response Voltage rise/fall ≤ 5 ms (representative 3U); transient recovery < 4.5 ms (10→60%)
Load modes CC / CV / CP / CR, with CC&CV priority
Simulation Battery (NS81000, 7 libraries + custom) · PV I-V/P-V (NS91000, EN50530/Sandia)
Protections OVP / OCP / OPP / UVP / UCP
Power factor 0.99
AC input Three-phase 340–480 VAC, 47–63 Hz
Interface LAN / RS232 / RS485 / CAN — SCPI, Modbus-RTU, CANopen
Display 6.8″ LCD
Operating environment 0–50 °C (derate > 35 °C); storage −10–70 °C; < 2000 m; 5–90% RH non-condensing
Standards / quality CE · IEC 61010-1 · ISO 17025-traceable calibration (on request)